Supply voltage VsDC 10 V … 30 V 1) 2)
Ripple≤ 5 Vpp 3)
Power consumption≤ 2.1 W 4)
Initialization time≤ 250 ms
Warm-up time≤ 15 min
Housing materialMetal (zinc diecast)
Window materialPlastic (PMMA)
Connection typeMale connector, M12, 5-pin
IndicationLC display, 2 x LED
Weight200 g
Dimensions (W x H x D)36.1 mm x 62.7 mm x 57.7 mm
Enclosure ratingIP65
Protection classIII
Measurement range min … max:200 mm … 10,000 mm, 90% remission factor
200 mm … 6,500 mm, 18 % remission
200 mm … 4,000 mm, 6% remission factor
TargetNatural objects
Resolution1 mm
Repeatability≥ 2.5 mm 1) 2) 3)
Accuracy± 10 mm 4)
Response time20 ms … 30 ms, 20 ms / 30 ms 3) 5)
Output time≥ 4 ms 6)
Light sourceLaser, red
visible red light
Laser class2 (IEC 60825-1:2014, EN 60825-1:2014) 7)
Typ. light spot size (distance)15 mm x 15 mm (10 m)
Additional functionSet moving average: fast/slow, switching mode: distance to object (DtO), teach-in, scaling and inversion of digital output, set hysteresis, teach-in, scaling and inversion of analog output, Multifunctional input: laser off / external teach / deactivated, switch-off display, reset to factory default, lock user interface
Average laser service life (at 25 °C)100,000 h
1) Equivalent to 1 σ.
2) 6% … 90% remission factor.
3) Dependent on the averaging setting: fast/slow.
4) 90% remission factor.
5) Lateral entry of the object into the measuring range.
6) Continuous change of distance in measuring range.
7) Wavelength: 658 nm; max. output: 180 mW; pulse duration: 5 ns; duty cycle: 1/200.
Digital output
Number1 1) 2)
TypePNP
Maximum output current IA≤ 100 mA
Analog output
Number1
TypeCurrent output
Current4 mA … 20 mA, ≤ 300 Ω
Resolution16 bit
Multifunctional input (MF)1 x 3) 4)
Hysteresis10 mm … 1,000 mm
1) Output Q short-circuit protected.
2) PNP: HIGH = VS– (< 2.5 V) / LOW = 0 V.3) Response time ≤ 15ms.4) PNP: HIGH = VS/ LOW = ≤ 2.5 V.