Ürün Açıklaması
Div. 2 Yangın çıkarmayan bariyer
Supply
Input current120 mA
Indicators/operating means
LED ONpower
Interface
Interface typeRS 232
Output
Output rated operating current200 mA
Output voltage4.6 VDC
Directive conformity
Electromagnetic compatibilityEN 50081-2, EN 61326, EN 61000-6-2, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Protection against electrical shockIEC 61140
Ambient conditions
Ambient temperature-40 … 60 °C (-40 … 140 °F)
Relative humidity< 95 % non-condensing
Vibration resistance5 G, 58 ... 150 Hz
Impact resistance15 g, 11 msMechanical specificationsConnection typeTerminal Block
Degree of protectionIP20
ConnectionSupply: terminals 13+, 14-
Input: terminals 9+, 10-
Output: terminals 1+, 2+, 3-, 4-
Mass120 g
Dimensions99 mm x 85 mm x 22.5 mm
Cable lengthCable length:
13.7 m (45') - barrier to barcode reader
13.7 m (45') - host pc to barrier
15.2 m (50') - total lengthData for application in connection with hazardous areasInput
Voltage9.95 V DC
Current450 mA
Internal capacitance20 µF
Internal inductance0.3 mHInternational approvalsUL approvalcULus (E106378)
Control drawing116-0337
Approved forClass I, Division 2, Groups A, B, C, and D
Class II, Division 2, Groups F and G
Class III, Division 2 Hazardous Locations