Ürün açıklaması
Polarizasyon filtreli retroreflektif sensör
General specifications
Effective detection range0 … 7.5 m
Reflector distance0.03 … 7.5 m
Threshold detection range10 m
Reference targetH85-2 reflector
Light sourceLED
Light typemodulated visible red light
LED risk group labellingexempt group
Polarization filteryes
Diameter of the light spotapprox. 65 mm at a distance of 1 m
Opening angle3.7 °
Ambient light limitEN 60947-5-2
Functional safety related parameters
MTTFd724 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green:
constantly on – power on
flashing (4Hz) – short circuit
flashing with short break (1 Hz) – IO-Link mode
Function indicatorYellow LED:
Permanently lit – light path clear
Permanently off – object detected
Flashing (4 Hz) – insufficient operating reserve
Control elementsLight-on/dark-on changeover switch
Control elementssensitivity adjustment
Parameterization indicatorIO link communication: green LED goes out briefly (1 Hz)
Electrical specifications
Operating voltage10 … 30 V DC
Ripplemax. 10 %
No-load supply current< 25 mA at 24 V supply voltage
Protection classIIIInterfaceInterface typeIO-Link ( via C/Q = pin 4 )
IO-Link revision1.1
Device ID0x110212 (1114642)
Transfer rateCOM2 (38.4 kBit/s)
Min. cycle time2.3 ms
Process data widthProcess data input 2 Bit
Process data output 2 Bit
SIO mode supportyes
Compatible master port typeAOutputStability alarm output1 PNP, inactive when level falls below function reserve after approx. 5 s.
Immediately inactive if the beam is interrupted 4 times during the flashtime.
Switching typeThe switching type of the sensor is adjustable. The default setting is:
C/Q - BK: PNP normally open / dark-on, IO-Link
Alarm output - WH: PNP normally closed
Signal output1 PNP, short-circuit protected, reverse polarity protected
Switching voltagemax. 30 V DC
Switching currentmax. 100 mA , resistive load
Usage categoryDC-12 and DC-13
Voltage drop≤ 1.5 V DC
Switching frequency1000 Hz
Response time0.5 msConformityCommunication interfaceIEC 61131-9
Product standardEN 60947-5-2Approvals and certificatesUL approvalE87056 , cULus Listed , class 2 power supply , type rating 1Ambient conditionsAmbient temperature-40 ... 60 °C (-40 ... 140 °F) , fixed cable
-25 ... 60 °C (-13 ... 140 °F) , movable cable not appropriate for conveyor chains
Storage temperature-40 ... 70 °C (-40 ... 158 °F)Mechanical specificationsHousing width11 mm
Housing height37.1 mm
Housing depth21.5 mm
Degree of protectionIP67 / IP69 / IP69K
Connection2 m fixed cable
Material
HousingPC (Polycarbonate)
Optical facePMMA
Massapprox. 36 g
Cable length2 m