Ürün Açıklaması
Tek kafalı sistem
General specifications
Sensing range60 … 550 mm
Dead band0 … 60 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox. 380 kHz
Response delay> 10 s, relay
< 1 s, LEDsIndicators/operating meansLED redLED 1: overfill indication
LED 4: underfill indication
LED green/yellowLED 2: overfill warning and normal operation
LED 3: normal operation and underfill warning
DIP switchsetting of the switch points/operating modesElectrical specificationsOperating voltage10 ... 253 V DC
20 ... 253 V AC , 47 ... 63 Hz
No-load supply current< 30 mA with UB = 30 V DC
< 110 mA at UB = 10 V DC
< 25 mA at UB = 220 V ACOutputOutput type3 relay outputs, normally open/closed, selectable
Range hysteresis20 mm
Contact loading253 V AC/150V DC, 3 A (ohm. load)
Life spanelectrical: 105 switching cycles with ohmic load
(3 A/253 V AC or 3 A/30 V DC)
minimum contact load: 100 µA/100 mV DC
mechanical: 20 x 106 switching cycles
Temperature influence< 4 %
Fusing≤ 3 A Slow-blow fuse per output in accordance with IEC 60127-2 Sheet 5 required. Recommendation: after a short circuit, check that the device is functioning correctly.Compliance with standards and directivesStandard conformity
StandardsEN IEC 60947-5-2:2020
IEC 60947-5-2:2019Approvals and certificatesCCC approvalself-declarationAmbient conditionsAmbient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)Mechanical specificationsHousing diameter75 mm
Degree of protectionIP65
ConnectionFemale connector, V7 (7-pin), 90°
Wire cross section: ≤1.5 mm2
cable diameter ∅7 ... 9 mm
Material
Housingcover: PC
housing: PBT
threaded flange: stainless steel
installation connector/cable socket: PETP
Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam
Mass700 g
NoteIn case of loss or damage, the cable socket must be replaced by an identical cable socket (type V7-W) from Pepperl+Fuchs!