| Measuring unit for lengths |
|
Metre/Millimetre |
|
| Generation |
2 |
Second generation |
|
| Application |
S |
Standard |
|
| Radar technology |
W |
80 GHz technology |
|
| Process fitting |
YD |
Compression flange suitable for flanges DN80 PN16 3″ 150lb / PP-GF30 |
|
| Antenna version |
B |
Plastic horn antenna |
|
| Additional equipment |
X |
without |
|
| Material / Seal / Process temperature |
AT |
PP / PP / -40…+80°C |
|
| Housing / Protection |
K |
Plastic single chamber / IP66/IP67 |
|
| Cable entry / Connection |
M |
M20x1.5 / Cable gland PA black (ø5-9mm), standard |
|
| Display, adjustment or radio module |
K |
Display/adjustment module PLICSCOM, with Bluetooth |
|
| Electronics |
H |
Two-wire 4 … 20 mA/HART |
|
| Explosion protection |
AX |
for Ex-free area (CE, RCM, UKCA; in preparation: EAC) |
|
| Functional safety SIL (IEC 61508) |
X |
without |
|
| IT security (IEC 62443-4-2) |
X |
without |
|
| Overfill protection (WHG/VLAREM/KVU) |
X |
without |
|
| Foodstuff/Pharmaceutical certificate |
X |
without |
|
| Ship approval (BV, RINA, ABS, DNV, CCS, ClassNK, LR) |
X |
without |
|
| Second Line of Defense |
X |
without |
|
| Type label |
|
of foil |
|
| Measurement loop identification label |
|
without |
|
| Customer-specific settings |
|
No |
|
| Test certificate |
|
without |
|
| Additional cleaning procedure (incl. 3.1 Inspection certificate oil, grease, silicone-free) |
|
without |
|
| Suitable for tropical regions (incl. 2.1 Factory certificate; all mounting parts of metal) |
|
without |
|
| Inspection certificate for material |
|
without |
|
| |
|
| Inspection certificate for instrument with test data (incl. 3.1 Inspection certificate EN 10204) |
|
without |
|
| Factory certificate for material (incl. 2.2 Factory certificate EN 10204) |
|
without |
|
| Quality and test plan |
|
without |
|
| Welding documentation |
|
without |
|
| Dye penetration test (incl. 3.1 Inspection certificate) |
|
without |
|
| Pressure test |
|
without |
|
| Helium leak test |
|
without |
|
| Radiographic test |
|
without |
|
| Roughness test (incl. 3.1 Inspection certificate) |
|
without |
|
| PMI test (incl. 3.1 Inspection certificate) |
|
without |
|
| Low temperature test at -60 °C (incl. 3.1 Inspection certificate) |
|
without |
|
| Durability test more than 360 h (incl. 3.1 Inspection certificate) |
|
without |
|
| Insulation resistance test (incl. 3.1 Inspection certificate) |
|
without |
|
| Customer-specific production |
|
without |
|
| Certification acc. to MCERTS |
|
without |
|
| Max. measuring range |
|
120 m |
|
| Operating instructions |
|
TR – Turkish |
|
| Number of operating instructions |
|
1 |
|
| Min. process pressure in bar |
|
-1 |
|
| Max. process pressure in bar |
|
2 |
|
| Customs tariff number (HS code) |
|
90318080 |
|
| Software version |
|
Current version |
|