VEGABAR 81 B81.AC3NC1GHSHXAIMAX Ürün Konfigürasyonu
Measuring unit for lengths | Metre / Millimetre | |
Measuring unit for pressure | bar | |
Scope | A | Europe |
Approval | C | ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 |
Process fitting / Material | 3N | Thread ½NPT inside PN160, ASME B1.20.1; diaphragm: inside / 316L |
Isolating liquid / Process temperature | C | Silicone oil and cooling element / -40…+250°C (Pabs<1bar -40…+150°C) |
Diaphragm material | 1 | 316L |
Pressure | G | Relative pressure (measurement against atmosphere) |
Measuring range | H | 0…+16.0bar (0…+1600kPa) |
Vacuum service | without | |
Customer-specific adjustment | No | |
Accuracy class | S | 0.20% |
Electronics | H | Two-wire 4 … 20 mA/HART |
Overvoltage protection of the supply cable | without | |
Additional electronics | X | without |
Housing | A | Aluminium single chamber |
Special colour | None | |
Housing version / Protection | I | compact / IP66/IP67; NEMA 4X |
Cable entry / Connection | M | M20x1.5 / Cable gland PA black (ø5-9mm), standard |
Display/Adjustment module PLICSCOM | A | mounted |
Certificates | X | No |
Operating instructions | EN – English | |
Number of operating instructions | 1 | |
Measurement loop identification label | without | |
Linearization | No | |
Address setting | No | |
Application-specific settings of parameters | without | |
Attached process seal | without | |
Electronic differential pressure | Suitable configuration |