VEGABAR 83 B83.ACDUSGTSHXAIMXX ÜRÜN KONFİGÜRASYONU
| Measuring unit for lengths | Metre / Millimetre | |
| Measuring unit for pressure | bar | |
| Scope | A | Europe |
| Approval | C | ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 |
| Process fitting / Material | DU | Thread G½, EN837; manometer connection / 316L |
| Process temperature / Seal | S | Standard -40…+105°C |
| Pressure | G | Relative pressure (measurement against atmosphere) |
| Measuring range | T | -1…0.0bar (-100…0kPa) |
| Customer-specific adjustment | No | |
| Accuracy class | S | 0.20% |
| Electronics | H | Two-wire 4 … 20 mA/HART |
| Overvoltage protection of the supply cable | without | |
| Supplementary electronics | X | without |
| Housing | A | Aluminium single chamber |
| Special colour | None | |
| Housing version / Protection | I | compact / IP66/IP67; NEMA 4X |
| Cable entry / Connection | M | M20x1.5 / Cable gland PA black (ø5-9mm), standard |
| Display/Adjustment module PLICSCOM | X | without |
| Certificates | X | No |
| Operating instructions | EN – English | |
| Number of operating instructions | 1 | |
| Measurement loop identification label | without | |
| Linearization | No | |
| Address setting | No | |
| Application-specific settings of parameters | without | |
| Measuring cell type | Piezoresistive – metallic measuring cell | |
| Attached process seal | Klingersil C-4400 | |
| Factor overload resistance measuring cell | 3 | |
| Electronic differential pressure | Suitable configuration | |
| Min. process pressure in bar | -1 bar | |
| Max. process pressure in bar | 2 bar |