VEGAPULS 6X PS6X – 223 S6T PS6X.2SWXXBXATAOXHARXXXXXX Ürün Konfigürasyonu
Measuring unit for lengths | Metre/Millimetre | |
Generation | 2 | Second generation |
Application | S | Standard |
Radar technology | W | 80 GHz technology |
Process fitting | XX | universal, plastic horn antenna / PP/PBT |
Antenna version | B | Plastic horn antenna |
Additional equipment | X | without |
Material / Seal / Process temperature | AT | PP / PP / -40…+80°C |
Housing / Protection | A | Aluminium single chamber / IP66/IP68 (0.2bar) |
Cable entry / Connection | O | M20x1.5 / Cable gland brass nickle plated (ø6-12mm) |
Display, adjustment or radio module | X | without display, adjustment or radio module, standard lid |
Electronics | H | Two-wire 4 … 20 mA/HART |
Explosion protection | AR | ATEX/UKEX; dust, protection by enclosure; Zone 20, 20/21, 21 |
Functional safety SIL (IEC 61508) | X | without |
IT security (IEC 62443-4-2) | X | without |
Overfill protection (WHG/VLAREM/KVU) | X | without |
Foodstuff/Pharmaceutical certificate | X | without |
Ship approval (BV, RINA, ABS, DNV, CCS, ClassNK, LR) | X | without |
Second Line of Defense | X | without |
Type label | of foil | |
Measurement loop identification label | without | |
Customer-specific settings | No | |
Test certificate | without | |
Additional cleaning procedure (incl. 3.1 Inspection certificate oil, grease, silicone-free) | without | |
Suitable for tropical regions (incl. 2.1 Factory certificate; all mounting parts of metal) | without | |
Inspection certificate for material | without | |
Inspection certificate for instrument with test data (incl. 3.1 Inspection certificate EN 10204) | without |
Factory certificate for material (incl. 2.2 Factory certificate EN 10204) | without | |
Quality and test plan | without | |
Welding documentation | without | |
Dye penetration test (incl. 3.1 Inspection certificate) | without | |
Pressure test | without | |
Helium leak test | without | |
Radiographic test | without | |
Roughness test (incl. 3.1 Inspection certificate) | without | |
PMI test (incl. 3.1 Inspection certificate) | without | |
Low temperature test at -60 °C (incl. 3.1 Inspection certificate) | without | |
Durability test more than 360 h (incl. 3.1 Inspection certificate) | without | |
Insulation resistance test (incl. 3.1 Inspection certificate) | without | |
Customer-specific production | without | |
Certification acc. to MCERTS | without | |
Max. measuring range | 120 m | |
Operating instructions | EN – English | |
Number of operating instructions | 1 | |
Min. process pressure in bar | -1 | |
Max. process pressure in bar | 2 | |
Customs tariff number (HS code) | 90318080 | |
Software version | Current version |